Vector Compact Marine air system
Welcome to YachtAid Marine’s ultimate guide, informed by the comprehensive Marine Air Systems manual from Taylor Made Environmental, Inc. (TME) – a leader in high-performance environmental control systems. This introduction embarks on a journey into the VECTOR COMPACT® Air Conditioner, a pivotal innovation in marine climate control, a product of TME’s extensive expertise in comfort systems for marine and other demanding environments.
Explore its state-of-the-art features, efficient functionality, and the optional PASSPORT® II Digital Controller. Get ready to enhance your marine experience with insights backed by YachtAid’s unparalleled product range and TME’s global leadership in environmental solutions.

marine air systems manual
Marine air systems manual
Dive into the realm of supreme marine comfort with the VECTOR COMPACT® Air Conditioner. YachtAid’s commitment to excellence is vividly captured in our detailed marine air systems manual, guiding you through the innovation, efficiency, and dedication embedded in every aspect of this remarkable system.
Designed for Excellence
The VECTOR COMPACT® transcends conventional design, ingeniously maximizing cabin space while delivering robust cooling performance. This space-efficient marvel is a product of meticulous engineering, a fact elaborately detailed in our marine air systems manual, ensuring your marine adventures are both comfortable and spacious.
Superior Cooling Technology
Featuring state-of-the-art compressors and resilient cupronickel condenser coils, this system sets the gold standard for marine air conditioning. The marine air systems manual delves into each component’s role in delivering consistent, top-tier performance, ensuring you stay cool as you conquer the seas.
Streamlined Installation
This device is synonymous with user-friendliness. Its design prioritizes ease of installation, making the setup process a breeze, ensuring a seamless and straightforward installation experience, allowing you to return to what you love most – sailing.
Unparalleled Maintenance Ease
This air conditioner is crafted to endure, with high-quality components that resist the harsh marine environment, ensuring that maintenance is nothing more than a simple, occasional check-up. This steadfast reliability means more time enjoying the seas and less time in the engine room.
A Testament to Sustainability
It’s not just an air conditioner; it’s a statement of YachtAid’s commitment to eco-friendly marine solutions. By optimizing energy use, it reduces your carbon footprint, making it a choice that benefits you and the planet.
With VECTOR COMPACT®, embrace powerful cooling performance that aligns with the vision of a sustainable future, making every journey not just a voyage, but a step towards a greener tomorrow.
Mastering the Mechanics: VECTOR COMPACT® Operation
The system’s operation is a marvel of precision, beginning with the blower drawing warm cabin air across the evaporator. Here, air heat is skillfully transferred to the refrigerant, initiating a transformative cooling cycle. The compressor plays a pivotal role, propelling the refrigerant through the condenser coil where it interacts with seawater, transferring the heat and completing the cycle.
This intricate process, detailed in the marine air systems manual, underscores the system’s capability to cool and heat efficiently, adapting to various seawater temperatures. The VECTOR COMPACT® is more than an air conditioner; it’s a sophisticated symphony of components working in harmony, ensuring your marine environment is nothing short of perfect.
Steps for Installing the VECTOR COMPACT® Marine Air System
Installing the VECTOR COMPACT® marine air system is a critical task that requires precision and adherence to specific guidelines. This guide will walk you through each step in detail, ensuring your system operates efficiently and safely.
Unpacking and Inspection:
- Carefully unpack each item, comparing with the packing list.
- Check for any shipping damages and notify the carrier if any are found.
Selecting the Right Location:
- Choose a location away from bilge or engine room areas.
- Ensure the area is sealed from direct access to bilge and engine room vapors.
- Install the unit as low as possible for optimal airflow, but never in the bilge or engine room areas.
Electrical and Plumbing Setup:
- Follow the marine air systems manual for electrical connections, ensuring proper grounding.
- Install the seawater system as per guidelines, ensuring the pump is mounted correctly and all connections are secure.
- Double-check all electrical connections for safety.
Condensate Drain Installation:
- Route the condensate drains properly, avoiding direct discharge into the bilge.
- Ensure the drains are set up to flow downhill to a sump pump.
Final Installation Checks:
- Ensure all parts are securely fastened and positioned correctly.
- Follow the marine air systems manual to check all settings and connections before the first operation.
Remember, these are high-level steps. For complete and detailed instructions, always refer to the VECTOR COMPACT® marine air systems manual. This will ensure that you adhere to all safety standards and installation procedures.
Prioritizing Safety During VECTOR COMPACT® Installation
Installing the VECTOR COMPACT® marine air system requires strict adherence to safety guidelines to ensure a secure and efficient setup. Understanding and implementing these safety precautions can significantly reduce potential hazards associated with the installation and servicing of the system.
Key Safety Considerations:
- Proper Installation Location: Select a location away from bilge or engine room areas to prevent exposure to harmful vapors.
- Handling Electrical Components: Exercise caution when dealing with electrical components, ensuring all connections are secure and the system is properly grounded.
- Managing Refrigerants: Adhere to regulations regarding the handling of refrigerants to prevent environmental harm.
- Temperature Awareness: Be aware of high compressor temperatures during operation.
For a detailed understanding of all safety measures, always refer to the marine air systems manual.

marine air systems manual
Condensate Drain Section for Marine Air Systems
In the effective implementation of marine air systems, such as the prestigious VECTOR COMPACT®, proper handling of condensate drainage is crucial. This marine air systems manual provides detailed guidance to ensure optimal and safe operation of your equipment.
Features of the Condensate Drain Pan
The condensate drain pan of the VECTOR COMPACT® is designed with a height of 1¾ inches, incorporating four strategically located drain points. In conditions of high humidity, the unit can generate approximately ½ gallon of condensate per hour. Given this significant volume, it’s essential to plan and execute an efficient route for condensate drainage.
Optimal Route for Drainage
To ensure maximum efficiency and protection of the marine air system, it’s crucial to direct the condensate drains downwards, leading them to a dedicated sump pump. It’s important to note that directing drains to the bilge is not recommended, as this can lead to maintenance and functionality issues.
Post-Installation Verification and Testing
Once the installation of the condensate drain is complete, it’s crucial to perform a test to verify the correct flow of the system. This test involves pouring a quart of water into the pan and observing the efficiency of the drainage.
Detailed Installation Process
- Equipment Preparation: Start by removing the watertight plug located at the back of the base pan of the air conditioning unit.
- Component Assembly: Place the solid washer and then the liquid-seal washer onto the PVC fitting, following this specific order.
- Fitting Assembly: Insert the fitting through the exposed hole in the base pan, securing it with the corresponding locking nut.
- Seal Securing: Use two wrenches to firmly tighten and ensure a proper seal.
- Hose Connection: Attach a reinforced hose with an internal diameter of 5/8 inches to the hose barb, and secure it with stainless steel hose clamps.
- Drain Hose Routing: Install the drain hose on a downward slope from the unit, directing it aft and to a sump.
- Dual Drain Option: If using two drain fittings, the hoses can be joined in a “T” connection, ensuring to maintain a minimum of 2 inches of drop from the bottom of the base pan to the connection.
By following these detailed instructions, you ensure a successful and efficient installation of the condensate drainage system for your marine air system, guaranteeing optimal performance and extending the lifespan of your VECTOR COMPACT® equipment.
Blower Assembly for VECTOR COMPACT®
Multi-directional Air Discharge: The VECTOR COMPACT® allows for a flexible air supply. With the ability to rotate the blower up to 130 degrees, you can achieve multi-directional supply air discharge from a single unit. This feature is particularly beneficial for tight installation spaces.
Ease of Maintenance and Adjustment: The blower’s advanced design simplifies maintenance and adjustment. You can easily remove the blower for rotation or servicing. This is done by releasing just one stainless steel clamp and unscrewing two mounting ring screws.
Optimized Air Flow: For enhanced performance, rotate the blower to direct the air flow as directly as possible towards the supply air grille. This ensures efficient distribution of air throughout the space.
Mounting Brackets
Dual-Function Base Pan: The air conditioning (a/c) unit comes with a base pan that doubles as a condensate pan. This innovative design simplifies the structure and enhances functionality.
Secure Installation: The unit includes mounting clip brackets and screws (4 in total) to firmly secure the base pan to a flat, horizontal surface. Ensure that the installation surface is stable and even for optimal operation and safety.

marine air systems manual
Ducting Guidelines for Marine Air Systems
Proper ducting is paramount for the optimal performance of marine air systems, as outlined in this marine air systems manual. The efficiency and effectiveness of the system significantly depend on the quality and configuration of the ducting installation.
Ducting Installation Essentials
Airflow Efficiency: Maintain ducting as straight, smooth, and taut as possible. Minimize the number of 90-degree bends, as just two tight bends can lead to a 25% reduction in airflow.
Duct Sizing: Adhere to the guidelines for minimum duct diameters and their corresponding minimum area for supply and return air grilles in square inches. When using a transition box, ensure the total area of supply air ducts exiting the box at least equals the area of the supply duct feeding into the box.
Area Calculation for Round Ducts: To calculate the square inch area of a round duct, use the formula: Area = π * r² (where r is the radius of the duct).

marine air systems manual
Proper Ducting Connections: Step-by-Step
- Inner Duct Exposure: Pull back the fiberglass insulation to reveal the inner mylar duct hose.
- Mylar Duct Attachment: Slide the mylar duct hose over the mount ring until it is fully seated.
- Secure Attachment: Affix 3 or 4 stainless steel sheet metal screws through the duct hose into the transition ring. Ensure the screws capture the wire in the duct hose. Avoid using band clamps as they may lead to slippage.
- Sealing the Joint: Encircle the joint between the ducting and ring with duct tape to prevent any air leaks.
- Insulation Replacement: Re-cover the mylar with the pulled-back insulation up to the ring and secure it with tape.
- Final Adjustments: Trim any excess ducting and employ the same connection methodology at the supply air grille.
General Ducting Recommendations
- Sizing: Choose duct sizes appropriate for each specific application.
- Installation: Ensure ducts are smooth, taut, and have minimal bends or loops.
- Securing: Fasten ducts securely to prevent sagging during boat operation.
- Trimming: Remove any excess length of ducting.
- Maintenance of Shape: Avoid flattening or kinking the ducting.
- Insulation: Insulate ducts in high heat load areas such as hull sides or mechanical compartments.
- Protection: Shield ducts properly against potential damage, especially when routed through open areas.
- By adhering to these guidelines detailed in the marine air systems manual, you can ensure efficient and reliable performance of your marine air conditioning system, maintaining comfort and functionality on board.
Seawater Pump and Plumbing Guidelines for Marine Air Systems
The installation of the seawater system is a critical component in the maintenance and performance of marine air systems. Following these guidelines will ensure that the seawater system supports the marine air systems effectively.
Seawater Pump Installation
Pump Positioning: The centrifugal circulation pump, a key component in marine air systems, should be mounted at least one foot below the waterline to maintain operation on any vessel tack. The pump can be installed either horizontally or vertically, but ensure the discharge is always above the inlet, with the pump head rotated toward the water flow direction.
Speed Scoop Intake: For optimal functioning of marine air systems, install the speed scoop intake as far below the water line and as close to the keel as possible, especially on sailboats. This positioning helps keep the intake submerged, preventing air from entering the system. Ensure the intake faces forward and is not shared with other pumps.
Mandatory Seawater Strainer: Place a seawater strainer between the shut-off valve (seacock) and the pump. This is crucial for protecting marine air systems from foreign matter. Note that not installing a strainer will void the pump warranty.
Plumbing Configuration
System Incline: Arrange the seawater system with an upward incline from the speed scoop & seacock, through the strainer, to the pump inlet, and then up to the marine air systems’ condenser coil inlet. Ensure the discharge from the marine air systems unit runs to the seawater outlet thru-hull fitting, located for visual water flow check and close to the waterline to minimize noise.
Hose Connections: Secure all hose connections with double/reversed stainless steel hose clamps and use Teflon tape on all threaded connections for marine air systems.
For more detailed information on maintaining and installing marine air systems, contact YachtAid Marine assessors. Following these steps meticulously will ensure the longevity and efficiency of your marine air systems.

marine air systems manual
Electrical Connections, Grounding, and Bonding in Marine Air Systems
Adhering to proper electrical connection, grounding, and bonding guidelines is essential for the safe and efficient operation of marine air systems. The following instructions, based on the marine air systems manual, outline the critical steps and considerations in the electrical setup of your marine air system.
Terminal Connections and Wiring
Terminal Strip: Each a/c unit in marine air systems has a terminal strip in the electric box, labeled for correct electrical supply connections, ground wires, and pump circuits. Consult the wiring diagram provided in both the electrical box and this marine air systems manual for guidance.
Circuit Protection: Use the correctly sized circuit breaker, as indicated on the a/c unit’s data plate label, to protect your marine air systems. A minimum of 12 AWG boat cable is recommended for supplying power to the a/c unit and the seawater pump. Secure all connections with ring or fork terminals.
Dedicated Circuit Breakers
Individual Breakers: Each a/c unit in marine air systems requires its own dedicated circuit breaker. For a single unit, the seawater pump can connect directly to the terminal strip without a separate breaker.
Multiple Units: In marine air systems with multiple a/c units using the same seawater pump, connect the pump wires to a Pump Relay Panel (PRP), which should have its own dedicated breaker (max 20 amp).
Grounding and Bonding
Safety and Compliance: Ensure all units in marine air systems are effectively grounded to minimize electrical shock risks. Adhere to ABYC electrical codes for field wiring and ensure power supply is within the unit’s operating voltage range.
Grounding Connections: Follow ABYC standards for AC and DC grounding connections in marine air systems. Validate the presence of these connections when servicing or replacing equipment.
Bonding to Ship’s System: Connect the a/c unit to the ship’s bonding system to prevent corrosion from stray electrical currents or voltage. Additionally, bond all pumps, metallic valves, and fittings in the seawater circuit that are isolated by PVC or rubber hoses to the vessel’s bonding system.
Three Phase Power Source
Phase Sequencing: For marine air systems with a three-phase power source, ensure the wiring and phase sequencing is correct. Follow marine wiring standards for color-coding and sequence connection. Incorrect wiring can lead to reverse operation and increased noise levels in compressors and pumps.
For a comprehensive understanding of installation and maintenance, refer to the marine air systems manual. Remember, failure to properly ground and bond the system will void the warranty for your marine air systems.
Manual Control Panel (MCP) Installation and Operation for Marine Air Systems
When installing and operating the Manual Control Panel (MCP) for your marine air systems, following the outlined steps will ensure proper functionality and maximize the performance of your system.
MCP Installation for Marine Air Systems
- Location and Orientation: Position the MCP within the cap tube length of the a/c unit. The 3-knob MCP can be mounted either vertically (as shown) or horizontally. The required cut-out size is 2.5” by 7.0”. Refer to the MCP for correct orientation during installation.
- Control Wires and Cap Tube Routing: After making the cut-out, carefully uncoil the copper cap tube with the return air sensor (copper bulb). Route the control wires and cap tube through the hole, ensuring you do not kink the cap tube, as this could impair the functionality of your marine air systems.
- Sensor Mounting: Install the return air sensor into the clips on the evaporator coil. If it’s not feasible to mount it on the coil, place it behind the return air grille, ensuring it’s in the return air stream for accurate temperature regulation in your marine air systems.
- Electrical Connections: Make all electrical connections according to the wiring diagram provided in the electric box or the operations manual of your marine air systems.
MCP Operation for Marine Air Systems
- Initial Setup: Open the seawater intake ball valve (sea cock). Ensure the SYSTEM SWITCH control knob is set to OFF and turn on the AC circuit breaker. If your marine air systems’ seawater pump has a separate circuit breaker, turn that on as well.
- Starting the System: Switch the SYSTEM SWITCH control knob to START. This activates the fan and seawater pump in your marine air systems. Set the THERMOSTAT control knob to the coolest setting by rotating it fully clockwise (or counter-clockwise for heat if your system supports reverse cycle).
- Seawater Discharge Check: Observe a steady, solid stream of seawater from the overboard discharge to ensure proper seawater flow in your marine air systems.
- Fan Operation: Adjust the FAN SPEED control knob clockwise to the highest setting and confirm that the fan is operating with steady airflow from the supply air grille.
- Compressor Activation: Turn the SYSTEM SWITCH to RUN to start the compressor. The indicator light should illuminate, signaling the active status of your marine air systems.
- Thermostat Setting: Allow your marine air systems to cool/heat the area sufficiently. Once the desired temperature is reached, slowly turn the thermostat knob towards the center position until you hear a click, and the indicator light turns off. This sets the thermostat to maintain a constant temperature.
- Heating Tips: For heating in ambient temperatures below 50°F, initially set the FAN SPEED control knob to low for the first 5-10 minutes. Once the unit heats up, increase the fan speed for higher heat output in your marine air systems.
- Thermostat Adjustment: The thermostat cycles the compressor on and off, providing an automatic changeover from cooling to heating (for reverse cycle units) with a 3.5°F differential. Adjusting the thermostat to the left after setting it for cooling will activate heating, and to the right for cooling.
- Reversing Valve Maintenance: For reverse cycle units in marine air systems, periodically energize the reversing valve by switching to HEAT for a few seconds once a month. This keeps the internal parts moving freely.
Note: After turning off your marine air systems, wait at least 30 seconds before restarting to prevent system strain.
For more detailed guidance on MCP installation and operation, consult the marine air systems manual and visit YachtAid Marine. Proper adherence to these steps will ensure the longevity and efficiency of your marine air systems.

marine air systems manual
Passport II Display Panel Installation for Marine Air Systems

marine air systems manual
Proper installation of the Passport II digital display panel is crucial for accurate room temperature sensing and efficient operation of marine air systems. Follow these guidelines from the marine air systems manual for optimal installation and performance.
Selecting the Location
Ideal Placement: Mount the display panel on an inside wall, slightly above mid-height of the cabin, in a location with freely circulating air. This allows the built-in air sensor to best sense the average temperature, crucial for maintaining the performance of marine air systems.
Avoidance Areas: Do not install the display in direct sunlight, near heat-producing appliances, or in a bulkhead where radiating temperatures may affect performance. Keep the display out of the supply air stream and away from supply or return air grilles to prevent skewed temperature readings in your marine air systems.
Installation Process
Cable Connection: Connect the display cable (15”/4.6m standard length with 8-pin connector) from the air conditioner’s circuit board to the back of the display panel. Ensure the display is mounted within the cable’s length (custom lengths available) for seamless integration with your marine air systems.
Securing the Display: Attach the display panel to a bulkhead using the provided adhesive strips. Prioritize cleaning the mounting surface with isopropyl alcohol (test on a hidden portion first) for a secure installation. If adhesive strips are unsuitable for direct application, use the plastic bulkhead adapter (sold separately), securing it with screws without over-tightening.
Optional Sensors and Mounting
Remote Air Sensor: If the display’s location is not ideal for accurate room temperature sensing, consider using an optional remote air sensor. Mount this sensor in the return air stream, behind the return air grille, and connect its cable (7’/2.1m standard length with 6-pin connector) to socket #J2 on the circuit board. This will override the faceplate sensor, enhancing the performance of your marine air systems.
Outside Air Temperature (O.A.T.) Sensor: For external temperature readings, plug the O.A.T. cable into the 6-pin socket #J3. Mount the sensor in a protected location, away from direct sunlight. Remember, air sensor cables come in various lengths, so choose one that best fits your installation needs for marine air systems.
Cable Management: Secure all cables neatly, ensuring not to staple them during mounting, to maintain the integrity and performance of your marine air systems.
For comprehensive guidance on the installation and operation of the Passport II display panel in conjunction with your marine air systems, refer to the marine air systems manual. Proper adherence to these steps will ensure accurate temperature control and efficient operation of your marine air systems.
Modes of Operation for Marine Air Systems
Understanding the various modes of operation for the Passport II control panel is essential for the optimal use of your marine air systems. Each mode is designed to cater to specific climate control needs.
Cool Only Mode
- Operation: In cool only mode, the system operates the cooling function as required.
- Temperature Control: If the ambient temperature drops below the set point, the system will not automatically switch to heating mode. This ensures consistent cooling as per the marine air systems manual guidelines.
Heat Only Mode
- Operation: When set to heat only mode, the system activates the heating function as needed.
- Temperature Control: Should the room temperature rise above the set point, the system will not automatically transition to cooling mode, maintaining a steady heating environment as specified in the marine air systems manual.
Automatic Mode
- Functionality: This mode enables both heating and cooling operations based on the room’s requirements.
- Indicators and Control: The heat and cool LED indicators will signal the active mode. A temperature differential of 2°F is maintained within a mode. To change modes, a 4°F difference is required, ensuring precise temperature management as per the marine air systems manual.
Humidity Mode
- Activation: Engage this mode by pressing the POWER and DOWN buttons simultaneously.
- Operation: The system circulates air every four hours for thirty minutes, recording the air temperature.
If the temperature needs to be reduced, the cooling cycle starts and continues until a 2°F reduction is achieved or until the compressor has run for a maximum of one hour. This cycle repeats every four hours, with the cool LED indicator active when the compressor is running.
This mode is ideal for maintaining specific temperature and humidity levels, especially when the vessel is unoccupied for extended periods, as noted in the marine air systems manual.
Automatic Fan Mode
- Activation: Hold the FAN button until the letter “A” appears in the display.
- Functionality: The control adjusts fan speeds based on room temperature proximity to the set point. As the temperature approaches the set point, the fan speed decreases, balancing efficient temperature control and minimal fan operation. This feature is detailed in the marine air systems manual, including how to reverse fan speeds in heat mode under programmable parameter “U 9”.
Manual Fan Mode
- Activation: Hold the FAN button during normal operation to choose from six fan speeds.
- Operation: Speed “6” is the highest, and “1” is the lowest. The fan LED will light up when a manual speed is selected. The marine air systems manual also explains how to refine high and low fan speeds further by adjusting the fan limits under programming modes “U 2” and “U 3”.
Circulation Mode (Fan Only)
- Activation: With the system off, hold the FAN button until the desired speed, ranging from “1” (slow) to “6” (fast), is displayed.
- Operation: To turn the fan off, press and hold the FAN button until the number “0” appears. This mode is used for air circulation without heating or cooling, as described in the marine air systems manual.
Understanding and utilizing these modes will enhance the comfort and efficiency of your onboard climate control systems as part of your marine air systems.
Programming the Passport II for Marine Air Systems
Programming the Passport II is essential for optimizing the operation of marine air systems, allowing for adjustments based on installation variables such as ducting, sensor location, and system layout. Follow these steps to tailor the system for efficient operation and user flexibility.
Entering Program Mode
Activation: With the system off, press and hold the POWER button for five seconds until the letter “U” appears in the display window. Upon release, the first parameter setting “U 1” will be displayed.
Unlocking Program Mode: After entering program mode, simultaneously press and release the POWER and DOWN buttons.
Selecting and Changing Program Parameters
Parameter Selection: To browse through the parameters, press and hold the FAN button. Each parameter number indicates a different setting as described in the marine air systems manual.
Parameter Adjustment: Utilize the UP and DOWN buttons to select data or set desired limits. The range of parameter settings is available in the marine air systems manual.
Managing Default Settings
Resetting to Factory Defaults: If you wish to revert to factory settings, with the system off, press and hold the POWER button for ten seconds until the software version number (A##) is displayed.
Locking New Default Settings: After making the desired program changes and before exiting the program mode, simultaneously press and release the UP and DOWN buttons. This action overwrites the factory defaults. Record the new defaults for future reference, as recommended in the marine air systems manual.
Exiting Program Mode
Termination: To exit program mode, either press the POWER button or take no action for sixty seconds. The software version number will flash for one second before exiting the program mode.
For a comprehensive understanding of each parameter and how to tailor your marine air systems efficiently, consult the detailed descriptions provided in the marine air systems manual. Proper configuration ensures optimal performance and user satisfaction in managing your marine climate control systems.

marine air systems manual
Where Can I Find a Marine Air System?
If you’re searching for a reliable and efficient marine air system, you might have come across the VECTOR COMPACT® model in your research. Unfortunately, we must inform you that the VECTOR COMPACT® series has been discontinued due to it being an older version.
However, we’re excited to introduce you to the latest in marine climate control technology – the Dometic Turbo Units DTGX Models. These state-of-the-art systems are designed to provide exceptional performance, durability, and energy efficiency, ensuring a comfortable and enjoyable environment on your vessel.
To explore the features, benefits, and specifications of the Dometic Turbo Units DTGX Models, or to get personalized advice on the best system for your needs, simply click the button below.